Common Causes and Solutions of Yantai Fast Rolling Doors

1. Problem: Press the run button or remote control button of the quick door control box, the motor does not work and does not rotate. Causes and solutions:


(1) Motor failure, check whether the motor is faulty;


(2) The frequency command is not given or the frequency given is less than the starting frequency;


(3) The inverter is in a protection state, without resetting, reset first and then start;


(4) The peripheral wiring is wrong, check the peripheral wiring;


(5) The start button is faulty, the control line is disconnected, check the control line and button;


(6) The operation mode is set incorrectly. Check whether P102 is set to 1.


(7) The motor wires are not connected or missing, check the motor wires;


(8) The input terminal of the inverter is incorrectly defined and does not correspond to the peripheral wiring. Check the parameters of P315-P322;


(9) The inverter is faulty, check whether the inverter is faulty.


2. Problem: Overheating of fast door servo motor


Causes and solutions:


(1) The motor runs at a low speed, and the reduction ratio is improved to make the motor run at a higher speed.


(2) Insufficient voltage between phases of the motor, the switching action of the inverter will cause an impulse voltage between the windings of the motor unit, usually a large shock voltage will reach 3 times the input power voltage of the inverter, a dedicated motor is recommended;


(3) The motor insulation is lowered, replace the motor;


(4) The distance between the inverter and the motor is long. Please reduce the distance and install an AC reactor;


(5) The load is too large, the actual load has exceeded the rated torque of the motor, and the power or capacity of the motor should be increased;


(6) The ambient temperature is high. Please improve the ambient ventilation conditions and reduce the ambient temperature.


3. Problem: There are vibrations or abnormal noises in the fast rolling door machinery. Causes and solutions:


(1) If the machine is stuck or poorly lubricated, check the mechanical load;


(2) There is a resonance phenomenon in the machine. Adjust the carrier wave, change the reduction ratio, avoid the resonance frequency, and install vibration damping pads.


Up:
Down:
Back to list
Technical Support:Rya
  • No.188 Shixue Road, Zhifu District, Yantai City,
    Shandong Province
  • Tel:0535-6846120 6846130
  • Mobile:13806386636
  • Postcode:264000
  • Fax:0535-6846160
  • E-mail:ytokszj@vip.163.com

Scan to join us

Copyright ? Yantai Okedoor Industry Co., Ltd. Welcome to inquire!